LOGIC — Single Source of Fire Protection
Serving Los Angeles & Southern California · 24/7

One Source. One Call. Fire protection.

Southern California's trusted partner for comprehensive fire safety solutions — proudly serving Los Angeles and its surrounding regions. Fully licensed and certified for residential, commercial and high-rise properties.

NFPA 25NFPA 20NFPA 72NFPA 101NFPA 99Title 19Reg 4JCAHO
15+ yrs
Industry experience
All SoCal
LA & surrounding
24/7
Emergency response
NFPA
Fully compliant
About Logic Fire Protection

Southern California's trusted fire safety partner.

At Logic Fire Protection, we're Southern California's trusted partner for comprehensive fire safety solutions, proudly serving Los Angeles and its surrounding regions. Fully licensed and certified, with a deep understanding of fire protection needs, we cater to residential, commercial, and high-rise properties with unmatched expertise. Our mission is simple yet powerful: to deliver tailored, top-quality services that meet NFPA regulations and exceed industry expectations, ensuring your safety and compliance. Guided by our slogan, "One Source, One Call," we streamline the process — offering everything you need through a single, dependable contact.

Our team excels in navigating the testing, maintenance, and reporting requirements of local and state fire departments, insurance providers, hospitality standards, corporate guidelines, and healthcare mandates, including those enforced by JCAHO. Certified for Title 19 and Reg 4 testing, repair, and maintenance, we align our work with fire department specifications, delivering detailed documentation to keep your property compliant.

Beyond fire department certifications, many of our technicians hold specialized credentials, such as NFPA 25 (sprinkler systems), NFPA 20 (fire pumps), NFPA 72 (fire alarms), NFPA 101 (life safety), and NFPA 99 (healthcare facilities), ensuring precision across all sectors.

Services we provide

A complete fire protection program, under one roof.

Logic Fire Protection offers a wide range of fire safety services for residential, commercial, and high-rise properties, all aligned with NFPA standards and local regulations.

01

Automatic Fire Sprinkler Systems

Engineered automatic sprinkler systems for every hazard class and occupancy type.

  • Wet pipe sprinklers for standard applications.
  • Pre-action sprinklers for areas with sensitive equipment.
  • Deluge systems for high-hazard environments.
  • Foam-water sprinklers for flammable liquid risks.
02

Manual Fire Sprinkler Systems

Manual and combination sprinkler configurations for targeted protection.

  • Dry pipe sprinklers for unheated spaces.
  • Manual control valve systems for targeted activation.
  • Combination manual/automatic setups.
  • Backflush capabilities for all sprinkler types.
03

Fire Alarms

Addressable and conventional alarm systems with full detection and notification.

  • Addressable systems for precise detection.
  • Conventional alarms for smaller properties.
  • Smoke and heat detectors.
  • Audible and visual notification devices.
04

Central Station Systems

UL-listed remote monitoring with real-time signal transmission.

  • Remote monitoring via UL-listed stations.
  • Fire alarm signal transmission.
  • Integration with sprinkler and suppression systems.
  • Real-time emergency alerts.
05

Building Communication Systems

Two-way fireman communication, EVAC and area-of-refuge intercoms.

  • Two-way fireman communication for high-rises.
  • Area of refuge intercoms.
  • Emergency voice/alarm communication systems.
  • Public address integration.
06

Distributed Antenna Systems (DAS) Testing

In-building radio frequency testing for public safety communication.

  • In-building radio frequency testing.
  • Public safety DAS for fire and police communication.
  • Cellular and Wi-Fi signal enhancement.
  • Compliance with local codes.
07

Standpipe Systems

Class I, II and III standpipes in automatic, manual and semi-automatic configurations.

  • Class I standpipes for fire department use.
  • Class II standpipes for occupant use.
  • Class III combination standpipes.
  • Automatic, manual, and semi-automatic configurations.
  • Fire jumpers for temporary water supply.
08

Fire Pumps

Electric, diesel and jockey pumps sized and certified for every building type.

  • Electric motor-driven pumps.
  • Diesel-driven pumps.
  • Jockey pumps for pressure maintenance.
  • Vertical turbine pumps for deep water sources.
09

Automatic Elevator Recall Systems

Phase I and II recall operation with smoke detector integration.

  • Phase I emergency recall operation.
  • Phase II firefighter service mode.
  • Smoke detector integration.
  • Shunt trip for power disconnection.
10

Automatic Closing Fire Assemblies

Fire doors, rolling shutters and smoke curtains for compartmentation.

  • Fire doors with fusible links.
  • Rolling steel fire shutters.
  • Smoke curtains for compartmentation.
  • Automatic window closures.
11

Emergency Lighting

Battery-backed exit signs and illuminated egress pathways.

  • LED exit signs with battery backup.
  • Wall-mounted emergency lights.
  • Ceiling-recessed units.
  • Self-testing illuminated pathways.
12

Reg 4 & Title 19 Testing

California-compliant annual, 5-year hydrostatic and functional testing.

  • Annual sprinkler system checks.
  • Five-year hydrostatic testing.
  • Fire alarm functionality tests.
  • Compliance reporting for California codes.
13

Hydrant Testing & Maintenance

Public and private hydrant inspections, color-coded per NFPA standards.

  • Public and private fire hydrants.
  • Flow and pressure testing.
  • Barrel and valve inspections.
  • Color coding per NFPA standards.
14

Smoke Control Systems

Mechanical and natural smoke removal with barrier integration.

  • Smoke exhaust fans.
  • Natural ventilation systems.
  • Mechanical smoke removal setups.
  • Smoke barrier integration.
15

Stairway Pressurization

Positive-pressure and multi-zone pressurization for high-rise life safety.

  • Positive pressure systems.
  • Multi-zone pressurization for high-rises.
  • Exhaust relief vents.
  • Smoke-proof enclosure testing.
16

Escape Ladders

Portable, fixed and foldable escape ladders for every property type.

  • Portable chain ladders for residences.
  • Fixed metal ladders for commercial use.
  • Foldable emergency escape options.
  • Roof access ladders for high-rises.
17

Inspections & Compliance

Visual and operational assessments per NFPA codes with full reporting.

  • Visual system assessments.
  • Operational testing per NFPA codes.
  • Detailed fire department reports.
  • Deficiency correction plans.
18

24/7 Emergency Services

After-hours repairs, leak response and urgent recertification — one number, around the clock.

  • After-hours system repairs.
  • Immediate leak or failure response.
  • Temporary fire watch services.
  • Urgent recertification support.

For property managers and building owners, staying compliant is critical to avoiding fire department issues. Logic Fire Protection is your go-to resource for safety and compliance, providing expert testing, repairs, certifications, and recertifications to keep your property in top shape.

Our expertise

Built for high-rises, hospitals and everything in between.

Our expertise extends beyond the City of Los Angeles, serving all surrounding areas in Southern California. We're skilled in addressing the distinct needs of high-rise buildings, hospitals, residential properties, commercial spaces, and industrial facilities. Our team is proficient in the protocols and documentation demanded by local and state fire authorities, insurance providers, hospitality standards, corporate policies, and healthcare organizations, including JCAHO requirements. Combined with our technicians' certifications in NFPA 25, NFPA 20, NFPA 72, NFPA 101, and NFPA 99, we deliver outstanding service across all industries.

High-rise buildings
Hospitals & healthcare
Residential complexes
Commercial & industrial
How it works

From first call to filed report — three steps.

01

Request a quote

Tell us about your property and we'll assess your systems, certifications and compliance status — typically within one business day.

02

Certification plan

We schedule inspections, testing and any repairs around your operations — coordinating with fire marshals, insurance and on-site teams.

03

Reports & filing

Full NFPA, Title 19 and Reg 4 documentation is prepared and submitted directly to the AHJ — you stay compliant without the paperwork.

Got a notice from LAFD?

Reg 4 non-compliance, explained.

Resolve a notice

In Los Angeles, every commercial property must submit annual Reg 4 testing for sprinklers, standpipes and fire pumps through the BRYCER reporting portal. Miss a deadline or fail a test and the LAFD issues a non-compliance notice — with fines and re-inspection fees stacking quickly.

We perform the required NFPA 25 testing, complete the BRYCER filing on your behalf, address deficiencies in the same visit when possible, and provide a clean compliance report you can hand to ownership, insurance or LAFD.

Our clients

The properties we protect.

Logic Fire Protection is honored to serve a wide-ranging clientele, including high-rise buildings, hospitals, residential complexes, commercial properties, and industrial facilities throughout Southern California. Some of our esteemed clients include:

Kaiser Permanente Facilities
IMT Residential
SouthPark Group
SRG Residential
Jamison Properties
Ross Morgan & Company AAMC
Hilton Hotel
Holiday Inn
Residence Inn
Jonathan Club DTLA
CBRE
Greystar Property Management
Pacific design center
Apple Inc.
RW Selby & Company
Onni Group
Staying Level
FAM Residential
A-Ju Property Management Co.
One Source, One Call

Service you can trust.

Choose LogicFire Protection for proven expertise and service you can trust. Contact us today—one call secures it all!